Atrius India Core FHIR Implementation Guide
0.1.0 - ci-build
Atrius India Core FHIR Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: https://atrius.in/fhir/r4/atrius-in/StructureDefinition/atrius-in-devicerequest-prohibited | Version: 0.1.0 | ||||
| Draft as of 2026-07-24 | Computable Name: AtriusInDeviceProhibited | ||||
| Other Identifiers: OID:1.3.6.1.4.1.66219.1.42.41 | |||||
Atrius India Core profile. Parent: FHIR R4. Structurally aligned with QI-Core. India terminology via NDHM ValueSets where noted. Legacy QI-Core projection: runtime-mapper.
Usages:
You can also check for usages in the FHIR IG Statistics
Description Differentials, Snapshots, and other representations.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
?! | 1..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 |
![]() ![]() ![]() |
?!S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform Constraints: ext-1 |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |
![]() ![]() |
?!SΣ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
![]() ![]() |
?!SΣ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. |
![]() ![]() |
SΣ | 1..1 | Device requested Slice: Unordered, Closed by type:$this Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |
![]() ![]() ![]() |
Reference(Device) | |||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Atrius India Core Device(0.1.0)) | Device requested |
![]() ![]() ![]() |
SΣ | 0..1 | CodeableConcept | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | canonical(ValueSet) | Url of a value set of activities URL: http://hl7.org/fhir/StructureDefinition/codeOptions Constraints: ext-1 |
![]() ![]() |
SΣ | 1..1 | Reference(Atrius India Core Patient(0.1.0)) | Focus of request |
![]() ![]() |
SΣ | 1..1 | dateTime | When recorded |
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceRequest.status | Base | required | RequestStatus | 📍4.0.1 | FHIR Std. |
| DeviceRequest.intent | Base | required | RequestIntent | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x] | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x]:codeCodeableConcept | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.reasonCode | Base | example | Condition/Problem/Diagnosis Codes | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | DeviceRequest.implicitRules, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.value[x], DeviceRequest.status, DeviceRequest.intent, DeviceRequest.code[x], DeviceRequest.code[x]:codeReference, DeviceRequest.code[x]:codeCodeableConcept, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.subject, DeviceRequest.authoredOn, DeviceRequest.reasonCode | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |
![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform |
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |
![]() ![]() |
1..1 | dateTime | When recorded | |
![]() ![]() |
S | 0..* | CodeableConcept | Coded Reason for request |
Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() |
?! | 1..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | ||||
![]() ![]() ![]() |
?!S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform Constraints: ext-1 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |||||
![]() ![]() |
Σ | 0..* | Identifier | External Request identifier | ||||
![]() ![]() |
Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
![]() ![]() |
Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What request fulfills | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What request replaces | ||||
![]() ![]() |
Σ | 0..1 | Identifier | Identifier of composite request | ||||
![]() ![]() |
?!SΣ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
![]() ![]() |
?!SΣ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. | ||||
![]() ![]() |
Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
![]() ![]() |
SΣ | 1..1 | Device requested Slice: Unordered, Closed by type:$this Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |||||
![]() ![]() ![]() |
Reference(Device) | |||||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Atrius India Core Device(0.1.0)) | Device requested | ||||
![]() ![]() ![]() |
SΣ | 0..1 | CodeableConcept | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | canonical(ValueSet) | Url of a value set of activities URL: http://hl7.org/fhir/StructureDefinition/codeOptions Constraints: ext-1 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..* | BackboneElement | Device details | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Device detail Binding Description: (example): A code that identifies the device detail. | |||||
![]() ![]() ![]() |
0..1 | Value of detail | ||||||
![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() |
SΣ | 1..1 | Reference(Atrius India Core Patient(0.1.0)) | Focus of request | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Encounter(0.1.0)) | Encounter motivating request | ||||
![]() ![]() |
Σ | 0..1 | Desired time or schedule for use | |||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
Timing | |||||||
![]() ![]() |
SΣ | 1..1 | dateTime | When recorded | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Practitioner(0.1.0) | Atrius India Core PractitionerRole(0.1.0) | Atrius India Core Organization(0.1.0) | Atrius India Core Device(0.1.0)) | Who/what is requesting diagnostics | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Practitioner(0.1.0) | Atrius India Core PractitionerRole(0.1.0) | Atrius India Core Organization(0.1.0) | Atrius India Core CareTeam(0.1.0) | Atrius India Core Patient(0.1.0) | Atrius India Core RelatedPerson(0.1.0) | Atrius India Core Device(0.1.0)) | Requested Filler | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
![]() ![]() |
Σ | 0..* | Reference(Atrius India Core Condition(0.1.0)) | Linked Reason for request | ||||
![]() ![]() |
0..* | Reference(Atrius India Core Coverage(0.1.0)) | Associated insurance coverage | |||||
![]() ![]() |
0..* | Reference(Resource) | Additional clinical information | |||||
![]() ![]() |
0..* | Annotation | Notes or comments | |||||
![]() ![]() |
0..* | Reference(Provenance) | Request provenance | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceRequest.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| DeviceRequest.status | Base | required | RequestStatus | 📍4.0.1 | FHIR Std. |
| DeviceRequest.intent | Base | required | RequestIntent | 📍4.0.1 | FHIR Std. |
| DeviceRequest.priority | Base | required | Request priority | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x] | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x]:codeCodeableConcept | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.parameter.code | Base | example | Not State | Unknown | |
| DeviceRequest.performerType | Base | example | Participant Roles | 📍4.0.1 | FHIR Std. |
| DeviceRequest.reasonCode | Base | example | Condition/Problem/Diagnosis Codes | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | DeviceRequest.meta, DeviceRequest.implicitRules, DeviceRequest.language, DeviceRequest.text, DeviceRequest.extension, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.extension, DeviceRequest.modifierExtension:doNotPerform.value[x], DeviceRequest.identifier, DeviceRequest.instantiatesCanonical, DeviceRequest.instantiatesUri, DeviceRequest.basedOn, DeviceRequest.priorRequest, DeviceRequest.groupIdentifier, DeviceRequest.status, DeviceRequest.intent, DeviceRequest.priority, DeviceRequest.code[x], DeviceRequest.code[x]:codeReference, DeviceRequest.code[x]:codeCodeableConcept, DeviceRequest.code[x]:codeCodeableConcept.extension, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.code[x]:codeCodeableConcept.coding, DeviceRequest.code[x]:codeCodeableConcept.text, DeviceRequest.parameter, DeviceRequest.parameter.extension, DeviceRequest.parameter.modifierExtension, DeviceRequest.parameter.code, DeviceRequest.parameter.value[x], DeviceRequest.subject, DeviceRequest.encounter, DeviceRequest.occurrence[x], DeviceRequest.authoredOn, DeviceRequest.requester, DeviceRequest.performerType, DeviceRequest.performer, DeviceRequest.reasonCode, DeviceRequest.reasonReference, DeviceRequest.insurance, DeviceRequest.supportingInfo, DeviceRequest.note, DeviceRequest.relevantHistory | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | DeviceRequest.extension, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.extension, DeviceRequest.code[x]:codeCodeableConcept.extension, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.parameter.extension, DeviceRequest.parameter.modifierExtension | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() |
?! | 1..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 |
![]() ![]() ![]() |
?!S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform Constraints: ext-1 |
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |
![]() ![]() |
?!SΣ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
![]() ![]() |
?!SΣ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. |
![]() ![]() |
SΣ | 1..1 | Device requested Slice: Unordered, Closed by type:$this Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |
![]() ![]() ![]() |
Reference(Device) | |||
![]() ![]() ![]() |
CodeableConcept | |||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Atrius India Core Device(0.1.0)) | Device requested |
![]() ![]() ![]() |
SΣ | 0..1 | CodeableConcept | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | canonical(ValueSet) | Url of a value set of activities URL: http://hl7.org/fhir/StructureDefinition/codeOptions Constraints: ext-1 |
![]() ![]() |
SΣ | 1..1 | Reference(Atrius India Core Patient(0.1.0)) | Focus of request |
![]() ![]() |
SΣ | 1..1 | dateTime | When recorded |
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. |
Documentation for this format | ||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceRequest.status | Base | required | RequestStatus | 📍4.0.1 | FHIR Std. |
| DeviceRequest.intent | Base | required | RequestIntent | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x] | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x]:codeCodeableConcept | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.reasonCode | Base | example | Condition/Problem/Diagnosis Codes | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | DeviceRequest.implicitRules, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.value[x], DeviceRequest.status, DeviceRequest.intent, DeviceRequest.code[x], DeviceRequest.code[x]:codeReference, DeviceRequest.code[x]:codeCodeableConcept, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.subject, DeviceRequest.authoredOn, DeviceRequest.reasonCode | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() |
|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |
![]() ![]() |
1..* | Extension | Extension Slice: Unordered, Open by value:url | |
![]() ![]() ![]() |
S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform |
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |
![]() ![]() |
1..1 | dateTime | When recorded | |
![]() ![]() |
S | 0..* | CodeableConcept | Coded Reason for request |
Documentation for this format | ||||
Snapshot ViewView
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() ![]() | ||||
|---|---|---|---|---|---|---|---|---|
![]() |
0..* | AtriusInDeviceRequest(0.1.0) | Medical device request | |||||
![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | |||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() |
?! | 1..* | Extension | Extension Slice: Unordered, Open by value:url Constraints: ext-1 | ||||
![]() ![]() ![]() |
?!S | 1..1 | (Complex) | R5: True if the request is to stop or not to start using the device (new) URL: http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform Constraints: ext-1 | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |||||
![]() ![]() ![]() ![]() |
0..1 | boolean | True if the request is to stop or not to start using the device Required Pattern: true | |||||
![]() ![]() |
Σ | 0..* | Identifier | External Request identifier | ||||
![]() ![]() |
Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
![]() ![]() |
Σ | 0..* | uri | Instantiates external protocol or definition | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What request fulfills | ||||
![]() ![]() |
Σ | 0..* | Reference(Resource) | What request replaces | ||||
![]() ![]() |
Σ | 0..1 | Identifier | Identifier of composite request | ||||
![]() ![]() |
?!SΣ | 0..1 | code | draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
![]() ![]() |
?!SΣ | 1..1 | code | proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. | ||||
![]() ![]() |
Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
![]() ![]() |
SΣ | 1..1 | Device requested Slice: Unordered, Closed by type:$this Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | |||||
![]() ![]() ![]() |
Reference(Device) | |||||||
![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() |
SΣ | 0..1 | Reference(Atrius India Core Device(0.1.0)) | Device requested | ||||
![]() ![]() ![]() |
SΣ | 0..1 | CodeableConcept | Device requested Binding: FHIRDeviceTypes (example): Codes for devices that can be requested. | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url Constraints: ext-1 | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
S | 0..1 | canonical(ValueSet) | Url of a value set of activities URL: http://hl7.org/fhir/StructureDefinition/codeOptions Constraints: ext-1 | ||||
![]() ![]() ![]() ![]() |
Σ | 0..* | Coding | Code defined by a terminology system | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Plain text representation of the concept | ||||
![]() ![]() |
0..* | BackboneElement | Device details | |||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Constraints: ext-1 | |||||
![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized Constraints: ext-1 | ||||
![]() ![]() ![]() |
0..1 | CodeableConcept | Device detail Binding Description: (example): A code that identifies the device detail. | |||||
![]() ![]() ![]() |
0..1 | Value of detail | ||||||
![]() ![]() ![]() ![]() |
CodeableConcept | |||||||
![]() ![]() ![]() ![]() |
Quantity | |||||||
![]() ![]() ![]() ![]() |
Range | |||||||
![]() ![]() ![]() ![]() |
boolean | |||||||
![]() ![]() |
SΣ | 1..1 | Reference(Atrius India Core Patient(0.1.0)) | Focus of request | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Encounter(0.1.0)) | Encounter motivating request | ||||
![]() ![]() |
Σ | 0..1 | Desired time or schedule for use | |||||
![]() ![]() ![]() |
dateTime | |||||||
![]() ![]() ![]() |
Period | |||||||
![]() ![]() ![]() |
Timing | |||||||
![]() ![]() |
SΣ | 1..1 | dateTime | When recorded | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Practitioner(0.1.0) | Atrius India Core PractitionerRole(0.1.0) | Atrius India Core Organization(0.1.0) | Atrius India Core Device(0.1.0)) | Who/what is requesting diagnostics | ||||
![]() ![]() |
Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
![]() ![]() |
Σ | 0..1 | Reference(Atrius India Core Practitioner(0.1.0) | Atrius India Core PractitionerRole(0.1.0) | Atrius India Core Organization(0.1.0) | Atrius India Core CareTeam(0.1.0) | Atrius India Core Patient(0.1.0) | Atrius India Core RelatedPerson(0.1.0) | Atrius India Core Device(0.1.0)) | Requested Filler | ||||
![]() ![]() |
SΣ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
![]() ![]() |
Σ | 0..* | Reference(Atrius India Core Condition(0.1.0)) | Linked Reason for request | ||||
![]() ![]() |
0..* | Reference(Atrius India Core Coverage(0.1.0)) | Associated insurance coverage | |||||
![]() ![]() |
0..* | Reference(Resource) | Additional clinical information | |||||
![]() ![]() |
0..* | Annotation | Notes or comments | |||||
![]() ![]() |
0..* | Reference(Provenance) | Request provenance | |||||
Documentation for this format | ||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| DeviceRequest.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| DeviceRequest.status | Base | required | RequestStatus | 📍4.0.1 | FHIR Std. |
| DeviceRequest.intent | Base | required | RequestIntent | 📍4.0.1 | FHIR Std. |
| DeviceRequest.priority | Base | required | Request priority | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x] | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.code[x]:codeCodeableConcept | Base | example | FHIR Device Types | 📍4.0.1 | FHIR Std. |
| DeviceRequest.parameter.code | Base | example | Not State | Unknown | |
| DeviceRequest.performerType | Base | example | Participant Roles | 📍4.0.1 | FHIR Std. |
| DeviceRequest.reasonCode | Base | example | Condition/Problem/Diagnosis Codes | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | DeviceRequest.meta, DeviceRequest.implicitRules, DeviceRequest.language, DeviceRequest.text, DeviceRequest.extension, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.extension, DeviceRequest.modifierExtension:doNotPerform.value[x], DeviceRequest.identifier, DeviceRequest.instantiatesCanonical, DeviceRequest.instantiatesUri, DeviceRequest.basedOn, DeviceRequest.priorRequest, DeviceRequest.groupIdentifier, DeviceRequest.status, DeviceRequest.intent, DeviceRequest.priority, DeviceRequest.code[x], DeviceRequest.code[x]:codeReference, DeviceRequest.code[x]:codeCodeableConcept, DeviceRequest.code[x]:codeCodeableConcept.extension, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.code[x]:codeCodeableConcept.coding, DeviceRequest.code[x]:codeCodeableConcept.text, DeviceRequest.parameter, DeviceRequest.parameter.extension, DeviceRequest.parameter.modifierExtension, DeviceRequest.parameter.code, DeviceRequest.parameter.value[x], DeviceRequest.subject, DeviceRequest.encounter, DeviceRequest.occurrence[x], DeviceRequest.authoredOn, DeviceRequest.requester, DeviceRequest.performerType, DeviceRequest.performer, DeviceRequest.reasonCode, DeviceRequest.reasonReference, DeviceRequest.insurance, DeviceRequest.supportingInfo, DeviceRequest.note, DeviceRequest.relevantHistory | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | DeviceRequest.extension, DeviceRequest.modifierExtension, DeviceRequest.modifierExtension:doNotPerform, DeviceRequest.modifierExtension:doNotPerform.extension, DeviceRequest.code[x]:codeCodeableConcept.extension, DeviceRequest.code[x]:codeCodeableConcept.extension:codeOptions, DeviceRequest.parameter.extension, DeviceRequest.parameter.modifierExtension | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Other representations of profile: CSV, Excel, Schematron